Our company aims to operating faithfully, serving to all of our shoppers , and working in new technology and new machine continuously for Factory supplied 100A Electromagnetic Residual Current Circuit Breaker Typeb 4p RCD/ELCB/RCBO/RCCB, We Sincerely welcome consumers from all over the planet to visit us, with our multifaceted cooperation and do the job together to create new markets, make win-win amazing long run.
Our company aims to operating faithfully, serving to all of our shoppers , and working in new technology and new machine continuously for RCCB and RCD, With the highest standards of product quality and service, our products and solutions have been exported to more than 25 countries like the USA, CANADA, GERMANY, FRANCE, UAE, Malaysia and so on.We’ve been very happy to serve customers from all over the world!
PID-125 can be used to cut off the fault circuit on the occasion of shock hazard or earth leakage of trunk line, It conforms to IEC61008.
1. Prevent leakage accidents at the source
2. Quick trip
3. Flexible combination, narrow product width, can save distribution box space
4. Humanized design and convenient installation
5. Simple and elegant appearance
6. Product operation is less affected by environmental factorsOur company aims to operating faithfully, serving to all of our shoppers , and working in new technology and new machine continuously for Factory supplied 100A Electromagnetic Residual Current Circuit Breaker Typeb 4p RCD/ELCB/RCBO/RCCB, We Sincerely welcome consumers from all over the planet to visit us, with our multifaceted cooperation and do the job together to create new markets, make win-win amazing long run.
Factory supplied RCCB and RCD, With the highest standards of product quality and service, our products and solutions have been exported to more than 25 countries like the USA, CANADA, GERMANY, FRANCE, UAE, Malaysia and so on.We’ve been very happy to serve customers from all over the world!
| Independent of line voltage | Yes |
| Dependent of line voltage | No |
| Rated voltage Ue:(V) | 230V or240V(1P+N):400V or 415V(3P+N) |
| Rated current in:(A) | 10A;16A;25A;20A;32A;40A;50A;63A;80A;100A;125A |
| Rated frequency:(Hz) | 50/60Hz |
| Rated residual operating current In:(A) | 30mA;100mA;300mA |
| Type | AC type and A type |
| Temporisation | Without time-delay |
| Nature of supply | ~ |
| Total number of poles | 1P+N and 3P+N(neutral on left |
| Rated insulation voitage Ui:(V) | 415V |
| Rated impulse withstandvoltageUimp:(V) | 4000V |
| Utilisation rangetemperature:(°C) | -5°℃ to +40℃ |
| Rated making and breaking capacityIm:(A) | 10In for 63A:80A:100A:125A500A for 10A:16A:25A:20A:32A40A:50A |
| Rated residual making and breaking capacity Im:(A) | Same as Im |
| Rated conditional short-circuit current Inc:(A) | 6000A |
| Rated conditional residual short-circuit current Ic:(A) | Same as Im |
| Short-circuit protection devices SCPDs used: | Silver wire |
| Grid distance(short-circuit tests): | 50mm |
| Protection against external influences: | Enclosed |
| Protection degree: | IP20 |
| Material group: | llla |
| Method of mounting: | On rail |
| Method of electrical connection | |
| not associated with the mechanical-mounting | Yes |
| associated with the mechanical-mounting | No |
| Type of terminals | Pillar terminal |
| Nominal diameter of thread:(mm) | 5.9mm |
| Operating means | Lever |