“Control the standard by the details, show the energy by quality”. Our enterprise has strived to establish a hugely efficient and stable staff members staff and explored an effective good quality control procedure for Rapid Delivery for a Type AC Type Magnetic Electronic Mode RCBO 10ka 2p 4p 63A 30mA 300mA 100mA, Special emphasis on the packaging of products to avoid any damage during transportation,Detailed attention to the valuable feedback and suggestions of our esteemed clients.
“Control the standard by the details, show the energy by quality”. Our enterprise has strived to establish a hugely efficient and stable staff members staff and explored an effective good quality control procedure for Breaker and AC Breaker, Besides strong technical strength, we also introduce advanced equipment for inspection and conduct strict management. All the staff of our company welcome friends both at home and abroad to come for visits and business on the basis of equality and mutual benefit. If you are interested in any of our items, remember to feel free to contact us for quotation and product details.
“Control the standard by the details, show the energy by quality”. Our enterprise has strived to establish a hugely efficient and stable staff members staff and explored an effective good quality control procedure for Rapid Delivery for a Type AC Type Magnetic Electronic Mode RCBO 10ka 2p 4p 63A 30mA 300mA 100mA, Special emphasis on the packaging of products to avoid any damage during transportation,Detailed attention to the valuable feedback and suggestions of our esteemed clients.
Rapid Delivery for Breaker and AC Breaker, Besides strong technical strength, we also introduce advanced equipment for inspection and conduct strict management. All the staff of our company welcome friends both at home and abroad to come for visits and business on the basis of equality and mutual benefit. If you are interested in any of our items, remember to feel free to contact us for quotation and product details.
RDB5LE-63 series residual current circuit breaker. The product is suitable for the circuit, rated working voltage 230/400V, rated current 32A, rated running shortcircuit breaking capacity is 6KA. For unfrequent circuit close, break & switch, with earthleakage, overload & shortcircuit protection. For unfrequent circuit close, break & switch.
Standard | IEC/EN 60947-3 | |||||||
Electrical features | Thermo-magnetic release characteristic | C, D | ||||||
Rated current In | A | 6, 10, 16, 20, 25, 32, 40, 50, 63 | ||||||
Rated voltage Ue | V | 230/ 400 | ||||||
Rated sensitivity l△n | A | 0.03, 0.1, 0.3 | ||||||
Rated residual making and breaking capacity I△m | A | 2000 | ||||||
Rated short-circuit capacity lcn | A | 6000 | ||||||
Break time under I△n | S | ≤0.1 | ||||||
Rated frequency | Hz | 1 | ||||||
Rated impulse withstand voltage Uimp | V | 4,000 | ||||||
Dielectric TEST voltage at ind. Freq. for 1min | kV | 2 | ||||||
Insulation voltage Ui | 600 | |||||||
Pollution degree | 2 | |||||||
Mechanical features | Electrical life | 4,000 | ||||||
Mechanical life | 10,000 | |||||||
Contact position indicator | Yes | |||||||
Protection degree | IP20 | |||||||
Ambient temperature(with daily average≤35℃) | ℃ | -5~+40 | ||||||
Storage temperature | ℃ | -25~+70 | ||||||
Installation | Terminal connection type | Cable/ U-type busbar/ Pin-type busbar | ||||||
Terminal size top for cable | m² | 25 | ||||||
Terminal size top for busbar | m² | 25 | ||||||
Tightening torque | N*m | 2 | ||||||
In-Ibs | 18 | |||||||
Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | |||||||
Connection | From top |
Overall and mounting Dimensions (mm).
A | B | C | D | 1P+N | 2P | 3P | 3P+N | 4P | |
RDB5LE-63 | 55 | 42 | 28 | 8 | 18+36 | 36+36 | 54+50 | 54+63 | 72+63 |
RDB5LE-63 series residual current circuit breaker. The product is suitable for the circuit, rated working voltage 230/400V, rated current 32A, rated running shortcircuit breaking capacity is 6KA. For unfrequent circuit close, break & switch, with earthleakage, overload & shortcircuit protection. For unfrequent circuit close, break & switch.
Standard | IEC/EN 60947-3 | |||||||
Electrical features | Thermo-magnetic release characteristic | C, D | ||||||
Rated current In | A | 6, 10, 16, 20, 25, 32, 40, 50, 63 | ||||||
Rated voltage Ue | V | 230/ 400 | ||||||
Rated sensitivity l△n | A | 0.03, 0.1, 0.3 | ||||||
Rated residual making and breaking capacity I△m | A | 2000 | ||||||
Rated short-circuit capacity lcn | A | 6000 | ||||||
Break time under I△n | S | ≤0.1 | ||||||
Rated frequency | Hz | 1 | ||||||
Rated impulse withstand voltage Uimp | V | 4,000 | ||||||
Dielectric TEST voltage at ind. Freq. for 1min | kV | 2 | ||||||
Insulation voltage Ui | 600 | |||||||
Pollution degree | 2 | |||||||
Mechanical features | Electrical life | 4,000 | ||||||
Mechanical life | 10,000 | |||||||
Contact position indicator | Yes | |||||||
Protection degree | IP20 | |||||||
Ambient temperature(with daily average≤35℃) | ℃ | -5~+40 | ||||||
Storage temperature | ℃ | -25~+70 | ||||||
Installation | Terminal connection type | Cable/ U-type busbar/ Pin-type busbar | ||||||
Terminal size top for cable | m² | 25 | ||||||
Terminal size top for busbar | m² | 25 | ||||||
Tightening torque | N*m | 2 | ||||||
In-Ibs | 18 | |||||||
Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | |||||||
Connection | From top |
Overall and mounting Dimensions (mm).
A | B | C | D | 1P+N | 2P | 3P | 3P+N | 4P | |
RDB5LE-63 | 55 | 42 | 28 | 8 | 18+36 | 36+36 | 54+50 | 54+63 | 72+63 |