RDL8-40 residual current circuit breaker with over-current protection is applicable to a circuit of AC50/60Hz, 230V (single phase), for overload, short circuit and residual current protection.
Electromagnetic type RCD.
Rated current up to 40A. It is mainly used in domestic installation, as well as in commercial and industrial electrical distribution systems.It conforms with the standard of IEC/EN61009.


  • Factory wholesale SAA Certificated 18mm 1p+N RCBO 6ka 16A RCCB with Overcurrent Protection for New Zealand Australia
  • Factory wholesale SAA Certificated 18mm 1p+N RCBO 6ka 16A RCCB with Overcurrent Protection for New Zealand Australia
  • Factory wholesale SAA Certificated 18mm 1p+N RCBO 6ka 16A RCCB with Overcurrent Protection for New Zealand Australia
  • Factory wholesale SAA Certificated 18mm 1p+N RCBO 6ka 16A RCCB with Overcurrent Protection for New Zealand Australia

Product Detail

Application

Parameters

Samples & Structures

Dimensions

With our abundant experience and considerate products and services, we have been recognized to be a reputable supplier for a lot of global consumers for Factory wholesale SAA Certificated 18mm 1p+N RCBO 6ka 16A RCCB with Overcurrent Protection for New Zealand Australia, Constantly for the majority of business enterprise users and traders to supply ideal top quality products and great service. Warmly welcome to join us, let’s innovation with each other, to flying dream.
With our abundant experience and considerate products and services, we have been recognized to be a reputable supplier for a lot of global consumers for 18mm RCBO and 4.5ka 20A RCBO, We follow up the career and aspiration of our elder generation, and we are eager to open up a new prospect in this field, We insist on “Integrity, Profession, Win-win Cooperation”, because we have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.

Product Introduction

With our abundant experience and considerate products and services, we have been recognized to be a reputable supplier for a lot of global consumers for Factory wholesale SAA Certificated 18mm 1p+N RCBO 6ka 16A RCCB with Overcurrent Protection for New Zealand Australia, Constantly for the majority of business enterprise users and traders to supply ideal top quality products and great service. Warmly welcome to join us, let’s innovation with each other, to flying dream.
Factory wholesale 18mm RCBO and 4.5ka 20A RCBO, We follow up the career and aspiration of our elder generation, and we are eager to open up a new prospect in this field, We insist on “Integrity, Profession, Win-win Cooperation”, because we have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.

RDL8-40 residual current circuit breaker with over-current protection is applicable to a circuit of AC50/60Hz, 230V (single phase), for overload, short circuit and residual current protection.
Electromagnetic type RCD.
Rated current up to 40A. It is mainly used in domestic installation, as well as in commercial and industrial electrical distribution systems.It conforms with the standard of IEC/ EN61009.

Main features

1. Supports all types of residual current protection: AC, A
2. Multiple breaking capacities for residential and industrial applications
3. Rated current up to 40A with user-defined poles for single-phase or three-phase grids
4. Rated residual current: 30mA, 100mA, 300mA

The role of RCBO

Residual current operated circuit breakers (RCBO) with overcurrent protection are mainly suitable for applications requiring both overcurrent protection (overload and short circuit) and earth fault current protection. It can detect faults and trip in time to ensure the safety of staff and equipment.

1

Technical specifications

     
Standard   IEC/EN 61009
Type (wave form of the earth leakage sensed)   AC, A
Thermo-magnetic  release  characteristic   B, C
Rated current In A 6, 10, 16, 20, 25, 32, 40
Poles   1P+N, 3P+N
Rated voltage Ue V 230/ 400-240/ 415
Rated sensitivity I△n A 0.03, 0.1, 0.3
Rated short-circuit capacity Icn A 6000
Break time under I△n s ≤0.1
Electrical life   4000 times
Mechanical life   4000 times
Mounting   On DIN rail EN60715(35mm)by means of fast clip device
Terminal  connection  type   Cable/ pin type busbar/ U type busbar

1 3 2

2

RDL8-40 residual current circuit breaker with over-current protection is applicable to a circuit of AC50/60Hz, 230V (single phase), for overload, short circuit and residual current protection.
Electromagnetic type RCD.
Rated current up to 40A. It is mainly used in domestic installation, as well as in commercial and industrial electrical distribution systems.It conforms with the standard of IEC/ EN61009.

Main features

1. Supports all types of residual current protection: AC, A
2. Multiple breaking capacities for residential and industrial applications
3. Rated current up to 40A with user-defined poles for single-phase or three-phase grids
4. Rated residual current: 30mA, 100mA, 300mA

The role of RCBO

Residual current operated circuit breakers (RCBO) with overcurrent protection are mainly suitable for applications requiring both overcurrent protection (overload and short circuit) and earth fault current protection. It can detect faults and trip in time to ensure the safety of staff and equipment.

1

Technical specifications

     
Standard   IEC/EN 61009
Type (wave form of the earth leakage sensed)   AC, A
Thermo-magnetic  release  characteristic   B, C
Rated current In A 6, 10, 16, 20, 25, 32, 40
Poles   1P+N, 3P+N
Rated voltage Ue V 230/ 400-240/ 415
Rated sensitivity I△n A 0.03, 0.1, 0.3
Rated short-circuit capacity Icn A 6000
Break time under I△n s ≤0.1
Electrical life   4000 times
Mechanical life   4000 times
Mounting   On DIN rail EN60715(35mm)by means of fast clip device
Terminal  connection  type   Cable/ pin type busbar/ U type busbar

1 3 2

2

  • Write your message here and send it to us