Reliable good quality and very good credit standing are our principles, which will help us at a top-ranking position. Adhering to your tenet of “quality 1st, purchaser supreme” for Wholesale Price Acereare Arw1-1600acb Air Circuit Breaker 3poles Acb OEM/ODM, We welcome clients, business associations and close friends from all components on the world to get in touch with us and request cooperation for mutual rewards.
Reliable good quality and very good credit standing are our principles, which will help us at a top-ranking position. Adhering to your tenet of “quality 1st, purchaser supreme” for Acb and Circuit Breaker, We always stick to the tenet of “sincerity, high quality, high efficiency, innovation”. With years of efforts, now we have established friendly and stable business relationships with worldwide customers. We welcome any of your inquiries and concerns for our products, and we have been sure that we’ll provide just what you want, as we always believe that your satisfaction is our success.
RDW5 series intelligent type Air circuit breaker is applied to power distribution network of AC 50/60Hz, rated operating voltage up to 400V/690V, rated current up to 6300A. It’s mainly used to distribute power and protect circuit and power-supply equipment against damage of faults, such as overload, under-voltage, short-circuit, single-phase grounding, and it has insulation function. Besides, the circuit breaker has various intelligent protect function, can realize bidirectional communication between several breaker and central control computer by its network system, realize remote control function to satisfied the requirements of automatic system control. The circuit breaker conforms the standard of IEC60947-2.
1.ECONOMICAL & FLEXIBLE
2.Quality Parts, Durability, Modular Design, Safe & Reliable
3.HIGHER electrical lifespan
4.More durable & Better performance
5.reduced maintenance cost
6.Innovaive ARC Extinguishing Design
7.Creating“CORE”design “WISDOM”for future
8.Compact in Size
9.Unique Secondary Terminal
10.Flexible Connection
11.Stringent environment capabilitiesReliable good quality and very good credit standing are our principles, which will help us at a top-ranking position. Adhering to your tenet of “quality 1st, purchaser supreme” for Wholesale Price Acereare Arw1-1600acb Air Circuit Breaker 3poles Acb OEM/ODM, We welcome clients, business associations and close friends from all components on the world to get in touch with us and request cooperation for mutual rewards.
Wholesale Price Acb and Circuit Breaker, We always stick to the tenet of “sincerity, high quality, high efficiency, innovation”. With years of efforts, now we have established friendly and stable business relationships with worldwide customers. We welcome any of your inquiries and concerns for our products, and we have been sure that we’ll provide just what you want, as we always believe that your satisfaction is our success.
Model No | RDW5-1600 | RDW5-2500 | RDWH-3200 | RDW5-4000 | RDW5-6300 | |||||
Rated current (A) | 200,400,630,800 1000,1250,1600 |
1000,1250,1600, 2000,2500 | 2000,2500,2900 3200,3600,4000 |
3200,3600,4000 | 400,050,006,300 | |||||
Neutral rated current In (A) | 100%In | 100%ln | 100%In | 100%In | 50%ln | |||||
Rated operating voltage (V) | AC400/690 | |||||||||
Frequency (Hz) | 50/60Hz | |||||||||
Number of poles | 3P/4P | |||||||||
Rated impulse withstand voltage Uimp(Kv) | Ad12 | |||||||||
Rated isolation voltage Ui(V) | AC 1000 | |||||||||
Power frequency withstand voltage (V) 1min | 3500 (Main circuit) | |||||||||
Rated ultimate short circuit breaking capacity (lcu) kA |
AC400V | 42 | 80 | 100 | 80 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated operating short circuit breaking capacity (lcs) kA |
AC400V | 32 | 65 | 80 | 65 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated withstand current for short- time (Icw) 1s(kA) |
AC400V | 20/30(0.5s) | 65 | 80 | 65 | |||||
AC690V | - | 40 | 50 | - | ||||||
Rated short circuit connection ability (Icm) kA | Electrical life | 7000 | 6500 | 3000 | 3000 | |||||
Mechanical life | 15000 | 15000 | 10000 | 10000 | ||||||
Using type | B type | |||||||||
Breaking time (without any auxiliary delay) | 25-30ms | |||||||||
Closing time | ≤70ms | |||||||||
Operation life (times) 2500A below | 400V electrical life |
8000 | 8000 | 5000 | 1500 | |||||
690V electrical life |
3000 | 2500 | 2000 | 1000 | ||||||
1time/3min; Above 2500A 1time/6min |
Mechanical life (maintenance-free) |
15000 | 12500 | 10000 | 6500 | |||||
Mechanical life (maintenance) |
30000 | 25000 | 20000 | 13000 | ||||||
Wire incoming pattern | Wire to enter from the upper or lower port | |||||||||
Arc distance (mm) | 0 | |||||||||
Installation method | Fixed type or draw-out type |
Draw-out type | Fixed type | ||||||||
Model | Poles | Width (mm) |
Height (mm) |
Depth mm) |
Weight (kg) |
Width (mm) |
Height (mm) |
Depth (mm) |
Weight (kg) |
RDW5-1600 | 3P | 282 | 351 | 345 | 43 | 254 | 320 | 254 | 22 |
4P | 352 | 351 | 345 | 55 | 324 | 320 | 254 | 26.5 | |
RDW5-2500 | 3P | 375 | 435 | 485 | 84 | 368 | 400 | 360 | 47 |
4P | 470 | 435 | 485 | 96 | 463 | 400 | 360 | 56 | |
RDW5-4000 | 3P | 435 | 435 | 515 | 100 | 428 | 400 | 392 | 53 |
4P | 550 | 435 | 515 | 130 | 543 | 400 | 392 | 67 | |
RDW5-6300 | 3P | 780 | 435 | 515 | 195 | 773 | 400 | 441 | 106 |
4P | 895 | 435 | 515 | 225 | 888 | 400 | 441 | 120 |
Overall dimension | Horizontal connection and overall dimension |
![]() |
RDW5-6300/3P Fixed type horizontal connection | Horizontal connection and phase spacing |
![]() |
Installation dimension | The relationship with busbar thickness and current | |
![]() |
Rated current A | Busbar thickness mm |
4000 | 20 | |
50006300 | 30 |
Overall dimension | Horizontal connection and overall dimension |
![]() |
RDW5-6300/4P Fixed type horizontal connection | Horizontal connection and phase spacing |
![]() |
Doorframe installation dimension of RDW5-4000-6300 fixed type | Installation dimension |
![]() |
Overall dimension | Horizontal connection and phase spacing | Installation dimension |
![]() |
RDW5-6300/3P The vertical connection of fixed type | Vertical connection and phase spacing |
![]() |
Overall dimension | Horizontal connection and overall dimension | Installation dimension |
![]() |
RDW5-6300/4P The horizontal connection of fixed type | Horizontal connection and phase spacing |
![]() |
RDW5-6300/4P The vertical connection of fixed type | Vertical connection and phase spacing |
![]() |
Model No | RDW5-1600 | RDW5-2500 | RDWH-3200 | RDW5-4000 | RDW5-6300 | |||||
Rated current (A) | 200,400,630,800 1000,1250,1600 |
1000,1250,1600, 2000,2500 | 2000,2500,2900 3200,3600,4000 |
3200,3600,4000 | 400,050,006,300 | |||||
Neutral rated current In (A) | 100%In | 100%ln | 100%In | 100%In | 50%ln | |||||
Rated operating voltage (V) | AC400/690 | |||||||||
Frequency (Hz) | 50/60Hz | |||||||||
Number of poles | 3P/4P | |||||||||
Rated impulse withstand voltage Uimp(Kv) | Ad12 | |||||||||
Rated isolation voltage Ui(V) | AC 1000 | |||||||||
Power frequency withstand voltage (V) 1min | 3500 (Main circuit) | |||||||||
Rated ultimate short circuit breaking capacity (lcu) kA |
AC400V | 42 | 80 | 100 | 80 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated operating short circuit breaking capacity (lcs) kA |
AC400V | 32 | 65 | 80 | 65 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated withstand current for short- time (Icw) 1s(kA) |
AC400V | 20/30(0.5s) | 65 | 80 | 65 | |||||
AC690V | - | 40 | 50 | - | ||||||
Rated short circuit connection ability (Icm) kA | Electrical life | 7000 | 6500 | 3000 | 3000 | |||||
Mechanical life | 15000 | 15000 | 10000 | 10000 | ||||||
Using type | B type | |||||||||
Breaking time (without any auxiliary delay) | 25-30ms | |||||||||
Closing time | ≤70ms | |||||||||
Operation life (times) 2500A below | 400V electrical life |
8000 | 8000 | 5000 | 1500 | |||||
690V electrical life |
3000 | 2500 | 2000 | 1000 | ||||||
1time/3min; Above 2500A 1time/6min |
Mechanical life (maintenance-free) |
15000 | 12500 | 10000 | 6500 | |||||
Mechanical life (maintenance) |
30000 | 25000 | 20000 | 13000 | ||||||
Wire incoming pattern | Wire to enter from the upper or lower port | |||||||||
Arc distance (mm) | 0 | |||||||||
Installation method | Fixed type or draw-out type |
Draw-out type | Fixed type | ||||||||
Model | Poles | Width (mm) |
Height (mm) |
Depth mm) |
Weight (kg) |
Width (mm) |
Height (mm) |
Depth (mm) |
Weight (kg) |
RDW5-1600 | 3P | 282 | 351 | 345 | 43 | 254 | 320 | 254 | 22 |
4P | 352 | 351 | 345 | 55 | 324 | 320 | 254 | 26.5 | |
RDW5-2500 | 3P | 375 | 435 | 485 | 84 | 368 | 400 | 360 | 47 |
4P | 470 | 435 | 485 | 96 | 463 | 400 | 360 | 56 | |
RDW5-4000 | 3P | 435 | 435 | 515 | 100 | 428 | 400 | 392 | 53 |
4P | 550 | 435 | 515 | 130 | 543 | 400 | 392 | 67 | |
RDW5-6300 | 3P | 780 | 435 | 515 | 195 | 773 | 400 | 441 | 106 |
4P | 895 | 435 | 515 | 225 | 888 | 400 | 441 | 120 |
Overall dimension | Horizontal connection and overall dimension |
![]() |
RDW5-6300/3P Fixed type horizontal connection | Horizontal connection and phase spacing |
![]() |
Installation dimension | The relationship with busbar thickness and current | |
![]() |
Rated current A | Busbar thickness mm |
4000 | 20 | |
50006300 | 30 |
Overall dimension | Horizontal connection and overall dimension |
![]() |
RDW5-6300/4P Fixed type horizontal connection | Horizontal connection and phase spacing |
![]() |
Doorframe installation dimension of RDW5-4000-6300 fixed type | Installation dimension |
![]() |
Overall dimension | Horizontal connection and phase spacing | Installation dimension |
![]() |
RDW5-6300/3P The vertical connection of fixed type | Vertical connection and phase spacing |
![]() |
Overall dimension | Horizontal connection and overall dimension | Installation dimension |
![]() |
RDW5-6300/4P The horizontal connection of fixed type | Horizontal connection and phase spacing |
![]() |
RDW5-6300/4P The vertical connection of fixed type | Vertical connection and phase spacing |
![]() |