OEM/ODM Supplier AC T2 40ka 4p Lightning Surge Power Protector Device SPD

RDSP6 series surge protection device, is mainly applied to the TN-C, TN-S, TT, IT power system of AC50Hz or 60Hz, nominal discharge current 5KA~60kA, Maximum discharge current 10KA~100KA, Rated operational voltage 220V or380 to protect the power grid from thunder shock overload and surge overload voltage. It is Widely applied to residential, transportation, electric power, the third industry and the industrial field of surge protection requirements.


  • OEM/ODM Supplier AC T2 40ka 4p Lightning Surge Power Protector Device SPD

Product Detail

Application

Parameters

Samples & Structures

Dimensions

We now have a expert, performance staff to deliver high quality provider for our customer. We usually follow the tenet of customer-oriented, details-focused for OEM/ODM Supplier AC T2 40ka 4p Lightning Surge Power Protector Device SPD, Hope we can create a more glorious future with you through our efforts in the future.
We now have a expert, performance staff to deliver high quality provider for our customer. We usually follow the tenet of customer-oriented, details-focused for Surge Protector and AC Surge Protector SPD, We take measure at any expense to achieve essentially the most up-to-date equipment and approaches. The packing of nominated brand is our a further distinguishing feature. The items to assure years of trouble-free service has attracted a great deal customers. The solutions are obtainable in improved designs and richer assortment, they’re created scientifically of purely raw supplies. It readily available in a variety of designs and specifications for your selection. The most recent kinds are a great deal better than the preceding one particular and they are quite popular with lots of prospects.

Product Introduction

RDSP6 series surge protection device, is mainly applied to the TN-C, TN-S, TT, IT power system of AC50Hz or 60Hz, nominal discharge current 5KA~60kA, Maximum discharge current 10KA~100KA, Rated operational voltage 220V or380 to protect the power grid from thunder shock overload and surge overload voltage. It is Widely applied to residential, transportation, electric power, the third
industry and the industrial field of surge protection requirements.

Surge Protection Device

Normal working condition and installation condition
Frequency: AC power frequency from 48Hz to 62Hz.
Voltage: Continuous voltage on the terminal should not exceed the maximum continuous operational voltage
Altitude: should not exceed 2000m
Using and storage Temperature:
Normal range: -5℃ ~+40℃
Limit temperature:-40℃~+70℃
Humidity: relative humidity should from 30% to 90%.Under the indoor humidity
Installation location without obvious impact and vibration, and the angle between the prodouct and vertical plane should not exceed 5°.We now have a expert, performance staff to deliver high quality provider for our customer. We usually follow the tenet of customer-oriented, details-focused for OEM/ODM Supplier AC T2 40ka 4p Lightning Surge Power Protector Device SPD, Hope we can create a more glorious future with you through our efforts in the future.
OEM/ODM Supplier Surge Protector and AC Surge Protector SPD, We take measure at any expense to achieve essentially the most up-to-date equipment and approaches. The packing of nominated brand is our a further distinguishing feature. The items to assure years of trouble-free service has attracted a great deal customers. The solutions are obtainable in improved designs and richer assortment, they’re created scientifically of purely raw supplies. It readily available in a variety of designs and specifications for your selection. The most recent kinds are a great deal better than the preceding one particular and they are quite popular with lots of prospects.

Surge main technical Parameter see Table1, Table2 Protective class: IP20 This product confrms to standard of IEC61643-1. Testing type: ll class Test. Surge protectors are used in a wide variety of electrical systems, such as homes, commercial and industrial equipment, and more. In electrical systems, they are usually installed at the power cables and at the incoming wires of electrical equipment.

Model No. Power grid operational voltage Ue(V) Maximum continous operational voltage Uc(V) Maximum discharge Imax(kA) Nominal discharge current In(kA) Protection module color Fuse (A) Wire diameter Respond timet(ns)
Phases,neutral line mm² ground line mm²
RDSP6-Ⅲ 220 360 420 10 5 White 10-16 hard line 25-10 two color 25-10 <25
RDSP6-Ⅲ 20 10
RDSP6-Ⅱ 40 20 Yellow 16-20 hard line 4-16 two color 4-16
RDSP6-Ⅱ
RDSP6-Ⅰ 60 30 Red 40-63 hard line 6-25 two color 6-25
RDSP6-Ⅰ 80 40
RDSP6-Ⅰ 100 60

RDSP6

12

Surge main technical Parameter see Table1, Table2 Protective class: IP20 This product confrms to standard of IEC61643-1. Testing type: ll class Test. Surge protectors are used in a wide variety of electrical systems, such as homes, commercial and industrial equipment, and more. In electrical systems, they are usually installed at the power cables and at the incoming wires of electrical equipment.

Model No. Power grid operational voltage Ue(V) Maximum continous operational voltage Uc(V) Maximum discharge Imax(kA) Nominal discharge current In(kA) Protection module color Fuse (A) Wire diameter Respond timet(ns)
Phases,neutral line mm² ground line mm²
RDSP6-Ⅲ 220 360 420 10 5 White 10-16 hard line 25-10 two color 25-10 <25
RDSP6-Ⅲ 20 10
RDSP6-Ⅱ 40 20 Yellow 16-20 hard line 4-16 two color 4-16
RDSP6-Ⅱ
RDSP6-Ⅰ 60 30 Red 40-63 hard line 6-25 two color 6-25
RDSP6-Ⅰ 80 40
RDSP6-Ⅰ 100 60

RDSP6