We know that we only thrive if we can guarantee our combined rate competiveness and good quality advantageous at the same time for New Arrival China Factory RCBO Overload Protection 2pole Type a AC 10mA 30mA 40AMP Dpn RCBO, We now have substantial goods source and also the rate is our advantage. Welcome to inquire about our merchandise.
We know that we only thrive if we can guarantee our combined rate competiveness and good quality advantageous at the same time for RCBO and RCCB, If you are for any reason unsure which product to select, do not hesitate to contact us and we are going to be delighted to advise and assist you. This way we are going to be providing you with all the knowledge needed to make the best choice. Our company strictly follows “Survive by good quality, Develop by keeping good credit. ” operation policy. Welcome all the clients old and new to visit our company and talk about the business. We have been looking for more and more customers to create the glorious future.
RDL6-40 residual current circuit breaker with overload protection is applicable to a circuit of AC50/60Hz, 230V (single phase), for overload, short circuit and residual current protection. Electromagnetic type RCD. Rated current up to 40A. It is mainly used in domestic installation, as well as in commercial and industrial electrical distribution systems.
It conforms with the standard of IEC/EN61009.
1. Process guaranteed performance
2. Small volume, large capacity
3. Super-strong wiring capacity
4. Good insulation between phases
5. Super-strong conductivity
6. Low temperature rise and power consumption
We know that we only thrive if we can guarantee our combined rate competiveness and good quality advantageous at the same time for New Arrival China Factory RCBO Overload Protection 2pole Type a AC 10mA 30mA 40AMP Dpn RCBO, We now have substantial goods source and also the rate is our advantage. Welcome to inquire about our merchandise.
New Arrival China RCBO and RCCB, If you are for any reason unsure which product to select, do not hesitate to contact us and we are going to be delighted to advise and assist you. This way we are going to be providing you with all the knowledge needed to make the best choice. Our company strictly follows “Survive by good quality, Develop by keeping good credit. ” operation policy. Welcome all the clients old and new to visit our company and talk about the business. We have been looking for more and more customers to create the glorious future.
RDL6-40 residual current circuit breaker with overload protection is applicable to acircuit of AC50/60Hz, 230V (single phase), for overload, short circuit and residualcurrent protection.
Electromagnetic type RCD.
Rated current up to 40A. It is mainly used in domestic installation, as well as incommercial and industrial electrical distribution systemslt conforms with the standardof IEC/EN61009.
Characteristic | Unit | Parameters | ||||||||||||
Standard | IEC/EN 61009 | |||||||||||||
Rated curType(wave form of the earth leakage sensed)rent In | AC, A | |||||||||||||
Thermo-magnetic release characteristic | B,C | |||||||||||||
Rated current In | A | 6,10,16,20,25,32,40 | ||||||||||||
Poles | 1P+N | |||||||||||||
Rated voltage Ue | V | 230/400-240/415 | ||||||||||||
Rated sensitivity I△n | A | 0.03,0.1,0.3 | ||||||||||||
Rated short-circuit capacity Icn | A | 4500 | ||||||||||||
Break time under I△n | S | ≤0.1 | ||||||||||||
Electrical life | 2000 times | |||||||||||||
Mechanical life | 2000 times | |||||||||||||
Mounting | On DIN rail EN60715(35mm)by means of fast clip device | |||||||||||||
Terminal connection type | Cable/pin type busbar/ U type busbar |
RDL6-40 residual current circuit breaker with overload protection is applicable to acircuit of AC50/60Hz, 230V (single phase), for overload, short circuit and residualcurrent protection.
Electromagnetic type RCD.
Rated current up to 40A. It is mainly used in domestic installation, as well as incommercial and industrial electrical distribution systemslt conforms with the standardof IEC/EN61009.
Characteristic | Unit | Parameters | ||||||||||||
Standard | IEC/EN 61009 | |||||||||||||
Rated curType(wave form of the earth leakage sensed)rent In | AC, A | |||||||||||||
Thermo-magnetic release characteristic | B,C | |||||||||||||
Rated current In | A | 6,10,16,20,25,32,40 | ||||||||||||
Poles | 1P+N | |||||||||||||
Rated voltage Ue | V | 230/400-240/415 | ||||||||||||
Rated sensitivity I△n | A | 0.03,0.1,0.3 | ||||||||||||
Rated short-circuit capacity Icn | A | 4500 | ||||||||||||
Break time under I△n | S | ≤0.1 | ||||||||||||
Electrical life | 2000 times | |||||||||||||
Mechanical life | 2000 times | |||||||||||||
Mounting | On DIN rail EN60715(35mm)by means of fast clip device | |||||||||||||
Terminal connection type | Cable/pin type busbar/ U type busbar |