New Arrival China Factory RCBO Overload Protection 2pole Type a AC 10mA 30mA 40AMP Dpn RCBO

RDL6-40 residual current circuit breaker with overload protection is applicable to a circuit of AC50/60Hz, 230V (single phase), for overload, short circuit and residual current protection. Electromagnetic type RCD.


  • New Arrival China Factory RCBO Overload Protection 2pole Type a AC 10mA 30mA 40AMP Dpn RCBO
  • New Arrival China Factory RCBO Overload Protection 2pole Type a AC 10mA 30mA 40AMP Dpn RCBO

Product Detail

Application

Parameters

Samples & Structures

Dimensions

We know that we only thrive if we can guarantee our combined rate competiveness and good quality advantageous at the same time for New Arrival China Factory RCBO Overload Protection 2pole Type a AC 10mA 30mA 40AMP Dpn RCBO, We now have substantial goods source and also the rate is our advantage. Welcome to inquire about our merchandise.
We know that we only thrive if we can guarantee our combined rate competiveness and good quality advantageous at the same time for RCBO and RCCB, If you are for any reason unsure which product to select, do not hesitate to contact us and we are going to be delighted to advise and assist you. This way we are going to be providing you with all the knowledge needed to make the best choice. Our company strictly follows “Survive by good quality, Develop by keeping good credit. ” operation policy. Welcome all the clients old and new to visit our company and talk about the business. We have been looking for more and more customers to create the glorious future.

Product Introduction

RDL6-40 residual current circuit breaker with overload protection is applicable to a circuit of AC50/60Hz, 230V (single phase), for overload, short circuit and residual current protection. Electromagnetic type RCD. Rated current up to 40A. It is mainly used in domestic installation, as well as in commercial and industrial electrical distribution systems.

It conforms with the standard of IEC/EN61009.

Features

1. Process guaranteed performance

2. Small volume, large capacity

3. Super-strong wiring capacity

4. Good insulation between phases

5. Super-strong conductivity

6. Low temperature rise and power consumption

RDB5-63-C16-1P-2_new1 (1)We know that we only thrive if we can guarantee our combined rate competiveness and good quality advantageous at the same time for New Arrival China Factory RCBO Overload Protection 2pole Type a AC 10mA 30mA 40AMP Dpn RCBO, We now have substantial goods source and also the rate is our advantage. Welcome to inquire about our merchandise.
New Arrival China RCBO and RCCB, If you are for any reason unsure which product to select, do not hesitate to contact us and we are going to be delighted to advise and assist you. This way we are going to be providing you with all the knowledge needed to make the best choice. Our company strictly follows “Survive by good quality, Develop by keeping good credit. ” operation policy. Welcome all the clients old and new to visit our company and talk about the business. We have been looking for more and more customers to create the glorious future.

RDL6-40 residual current circuit breaker with overload protection is applicable to acircuit of AC50/60Hz, 230V (single phase), for overload, short circuit and residualcurrent protection.
Electromagnetic type RCD.
Rated current up to 40A. It is mainly used in domestic installation, as well as incommercial and industrial electrical distribution systemslt conforms with the standardof IEC/EN61009.

192

Characteristic Unit Parameters
Standard   IEC/EN 61009
Rated curType(wave form of the earth leakage sensed)rent In   AC, A
Thermo-magnetic release characteristic   B,C
Rated current In A 6,10,16,20,25,32,40
Poles   1P+N
Rated voltage Ue V 230/400-240/415
Rated sensitivity I△n A 0.03,0.1,0.3
Rated short-circuit capacity Icn A 4500
Break time under I△n S ≤0.1
Electrical life   2000 times
Mechanical life   2000 times
Mounting   On DIN rail EN60715(35mm)by means of fast clip device
Terminal connection type   Cable/pin type busbar/ U type busbar

3

4

RDL6-40 residual current circuit breaker with overload protection is applicable to acircuit of AC50/60Hz, 230V (single phase), for overload, short circuit and residualcurrent protection.
Electromagnetic type RCD.
Rated current up to 40A. It is mainly used in domestic installation, as well as incommercial and industrial electrical distribution systemslt conforms with the standardof IEC/EN61009.

192

Characteristic Unit Parameters
Standard   IEC/EN 61009
Rated curType(wave form of the earth leakage sensed)rent In   AC, A
Thermo-magnetic release characteristic   B,C
Rated current In A 6,10,16,20,25,32,40
Poles   1P+N
Rated voltage Ue V 230/400-240/415
Rated sensitivity I△n A 0.03,0.1,0.3
Rated short-circuit capacity Icn A 4500
Break time under I△n S ≤0.1
Electrical life   2000 times
Mechanical life   2000 times
Mounting   On DIN rail EN60715(35mm)by means of fast clip device
Terminal connection type   Cable/pin type busbar/ U type busbar