Low price for Professional Miniature Circuit Breaker Manufacturer AC DC Dz47-63 1p 1- 63 AMP Mini MCB Switch RCCB/RCBO/ELCB/MCB/MCCB

RDX6-63 high breaking small circuit breaker, mainly used for AC 50Hz (or 60Hz), rated working voltage to 400V, rated current to 63A, rated short-circuit breaking force not exceeding 10000A rated current to 63A, rated short-circuit breaking force of not more than 10000A in the protection of power distribution lines, as the line infrequent connection, breaking and conversion, with overload, short-circuit protection function. At the same time, it has powerful auxiliary function modules, such as auxiliary contact, with alarm indication Contact, shunt striker, undervoltage striker, remote striker control and other modules.
The product conforms to GB/T 10963.1, IEC60898-1 standard.


  • Low price for Professional Miniature Circuit Breaker Manufacturer AC DC Dz47-63 1p 1- 63 AMP Mini MCB Switch RCCB/RCBO/ELCB/MCB/MCCB
  • Low price for Professional Miniature Circuit Breaker Manufacturer AC DC Dz47-63 1p 1- 63 AMP Mini MCB Switch RCCB/RCBO/ELCB/MCB/MCCB
  • Low price for Professional Miniature Circuit Breaker Manufacturer AC DC Dz47-63 1p 1- 63 AMP Mini MCB Switch RCCB/RCBO/ELCB/MCB/MCCB
  • Low price for Professional Miniature Circuit Breaker Manufacturer AC DC Dz47-63 1p 1- 63 AMP Mini MCB Switch RCCB/RCBO/ELCB/MCB/MCCB

Product Detail

Application

Parameters

Samples & Structures

Dimensions

Our solutions are widely regarded and trustworthy by consumers and may meet continually modifying financial and social requirements for Low price for Professional Miniature Circuit Breaker Manufacturer AC DC Dz47-63 1p 1- 63 AMP Mini MCB Switch RCCB/RCBO/ELCB/MCB/MCCB, You should send us your specifications and requirements, or feel totally free to speak to us with any questions or inquiries that you may have.
Our solutions are widely regarded and trustworthy by consumers and may meet continually modifying financial and social requirements for DC MCB and MCB DC, We are going to initiate the second phase of our development strategy. Our company regards “reasonable prices, efficient production time and good after-sales service” as our tenet. If you are interested in any of our solutions or would like to discuss a custom order, make sure you feel free to contact us. We have been looking forward to forming successful business relationships with new clients around the world in the near future.

Product Introduction

Our solutions are widely regarded and trustworthy by consumers and may meet continually modifying financial and social requirements for Low price for Professional Miniature Circuit Breaker Manufacturer AC DC Dz47-63 1p 1- 63 AMP Mini MCB Switch RCCB/RCBO/ELCB/MCB/MCCB, You should send us your specifications and requirements, or feel totally free to speak to us with any questions or inquiries that you may have.
Low price for DC MCB and MCB DC, We are going to initiate the second phase of our development strategy. Our company regards “reasonable prices, efficient production time and good after-sales service” as our tenet. If you are interested in any of our solutions or would like to discuss a custom order, make sure you feel free to contact us. We have been looking forward to forming successful business relationships with new clients around the world in the near future.

RDX6-63 miniature circuit breaker is applicable to a circuit of AC50/60Hz, 230V (single phase), 400V (2, 3, 4 phases), for overload and short circuit protection.
Rated current up to 63A. It also can be used as a switch for an infrequent conversion line. It is mainly used in domestic installation, as well as in commercial and industrial electrical distribution systems. It conforms with the standard of IEC/ EN60898.

Styling guide

RDX6 63 1P C 63A
Model no. Shell frame grade Number of poles Release type Rated current
miniature circuit breaker 63 1P
2P
3P
4P
C
D
(Customized B type available)
1A (white handle)
2A (white handle)
3A (white handle)
4A (white handle)
6A (greent handle)
10A (red handle)
16A (grey handle)
20A (blue handle)
25A (yellow handle)
32A (purple handle)
40A (black handle)
50A (white handle)
63A (red handle)

Normal operating conditions and installation conditions

Temperature: The upper limit of surrounding air temperature should not exceed +40℃, the lower limit should not be lower than -5℃, and the 24h average temperature should not exceed +35℃.
Altitude: The altitude of the installation site should not exceed 2000m.
Humidity: The relative humidity of the atmosphere does not exceed 50% when the ambient air temperature is +40℃. Higher relative humidity can be allowed at lower temperatures. Special measures should be taken for condensation that occasionally occurs on the surface of the product due to temperature changes.
Pollution level: Grade 2.
Installation conditions: Installed in a place without significant shock and vibration, and in a medium without explosion hazard.
Installation method: Installed with TH35-7.5 mounting rail.
Installation category: Class II, III.

Model No.

8

Product Categories

Rated voltage: 230V/400V (unipolar 230V, two-pole, three-pole and four-pole 400V);

Main technical data

The overcurrent release characteristics of the circuit breaker under normal installation conditions and reference ambient temperature (30-35)℃ are in accordance with the provisions of Table 1.
The main technical performance indicators of the circuit breaker are shown in Tables 1 and 2.

No. Tripping type  Rated current In  Test current A  Approximate time  Expected result  Starting state
1 C、D All values 1.13In t≤1h does not decouple cold state
2 C、D All values 1.45In t≤1h decouple immediately after the serial number 1 test
3 C、D ≤32A 2.55In 1s<t<60s decouple cold state
32A<In≤63A 1s<t<120s
4 C   5In t≤0.1s does not decouple cold state
D 10In
5 C All values 10In t≤0.1s decouple cold state
D 20In decouple
Tripping type Rated current A  Rated short-circuit breaking capacity A COSφ
C、D 1≤In≤63 10 000 0.45~0.50

1 2 3

Shape and installation dimensions

9

RDX6-63 miniature circuit breaker is applicable to a circuit of AC50/60Hz, 230V (single phase), 400V (2, 3, 4 phases), for overload and short circuit protection.
Rated current up to 63A. It also can be used as a switch for an infrequent conversion line. It is mainly used in domestic installation, as well as in commercial and industrial electrical distribution systems. It conforms with the standard of IEC/ EN60898.

Styling guide

RDX6 63 1P C 63A
Model no. Shell frame grade Number of poles Release type Rated current
miniature circuit breaker 63 1P
2P
3P
4P
C
D
(Customized B type available)
1A (white handle)
2A (white handle)
3A (white handle)
4A (white handle)
6A (greent handle)
10A (red handle)
16A (grey handle)
20A (blue handle)
25A (yellow handle)
32A (purple handle)
40A (black handle)
50A (white handle)
63A (red handle)

Normal operating conditions and installation conditions

Temperature: The upper limit of surrounding air temperature should not exceed +40℃, the lower limit should not be lower than -5℃, and the 24h average temperature should not exceed +35℃.
Altitude: The altitude of the installation site should not exceed 2000m.
Humidity: The relative humidity of the atmosphere does not exceed 50% when the ambient air temperature is +40℃. Higher relative humidity can be allowed at lower temperatures. Special measures should be taken for condensation that occasionally occurs on the surface of the product due to temperature changes.
Pollution level: Grade 2.
Installation conditions: Installed in a place without significant shock and vibration, and in a medium without explosion hazard.
Installation method: Installed with TH35-7.5 mounting rail.
Installation category: Class II, III.

Model No.

8

Product Categories

Rated voltage: 230V/400V (unipolar 230V, two-pole, three-pole and four-pole 400V);

Main technical data

The overcurrent release characteristics of the circuit breaker under normal installation conditions and reference ambient temperature (30-35)℃ are in accordance with the provisions of Table 1.
The main technical performance indicators of the circuit breaker are shown in Tables 1 and 2.

No. Tripping type  Rated current In  Test current A  Approximate time  Expected result  Starting state
1 C、D All values 1.13In t≤1h does not decouple cold state
2 C、D All values 1.45In t≤1h decouple immediately after the serial number 1 test
3 C、D ≤32A 2.55In 1s<t<60s decouple cold state
32A<In≤63A 1s<t<120s
4 C   5In t≤0.1s does not decouple cold state
D 10In
5 C All values 10In t≤0.1s decouple cold state
D 20In decouple
Tripping type Rated current A  Rated short-circuit breaking capacity A COSφ
C、D 1≤In≤63 10 000 0.45~0.50

1 2 3

Shape and installation dimensions

9

  • Write your message here and send it to us