It can be our duty to satisfy your preferences and successfully serve you. Your pleasure is our best reward. We have been looking forward to the go to for joint expansion for Leading Manufacturer for Acb CE Certification 1250A 3p/4p Air Circuit Breaker, We are hunting ahead to building positive and beneficial links with the businesses round the globe. We warmly welcome you to definitely call us to begin discussions on how we can easily bring this into being.
It can be our duty to satisfy your preferences and successfully serve you. Your pleasure is our best reward. We have been looking forward to the go to for joint expansion for Acb and Conventional Air Circuit Breaker, With the growing of the company, now our items sold and served at more than 15 countries around the world,such as Europe,North America,Middle-east,South America,Southern Asia and so on. As we bear in our mind that innovation is essential to our growth, new product development is constantly.Besides, Our flexible and efficient operation strategies,High quality products and solutions and competitive prices are exactly what our customers are looking for. Also a considerable service brings us good credit reputation.
RDW5 series intelligent type Air circuit breaker is applied to power distribution network of AC 50/60Hz, rated operating voltage up to 400V/690V, rated current up to 6300A. It’s mainly used to distribute power and protect circuit and power-supply equipment against damage of faults, such as overload, under-voltage, short-circuit, single-phase grounding, and it has insulation function. Besides, the circuit breaker has various intelligent protect function, can realize bidirectional communication between several breaker and central control computer by its network system, realize remote control function to satisfied the requirements of automatic system control. The circuit breaker conforms the standard of IEC60947-2.
1.ECONOMICAL & FLEXIBLE
2.Quality Parts, Durability, Modular Design, Safe & Reliable
3.HIGHER electrical lifespan
4.More durable & Better performance
5.reduced maintenance cost
6.Innovaive ARC Extinguishing Design
7.Creating“CORE”design “WISDOM”for future
8.Compact in Size
9.Unique Secondary Terminal
10.Flexible Connection
11.Stringent environment capabilitiesIt can be our duty to satisfy your preferences and successfully serve you. Your pleasure is our best reward. We have been looking forward to the go to for joint expansion for Leading Manufacturer for Acb CE Certification 1250A 3p/4p Air Circuit Breaker, We are hunting ahead to building positive and beneficial links with the businesses round the globe. We warmly welcome you to definitely call us to begin discussions on how we can easily bring this into being.
Leading Manufacturer for Acb and Conventional Air Circuit Breaker, With the growing of the company, now our items sold and served at more than 15 countries around the world,such as Europe,North America,Middle-east,South America,Southern Asia and so on. As we bear in our mind that innovation is essential to our growth, new product development is constantly.Besides, Our flexible and efficient operation strategies,High quality products and solutions and competitive prices are exactly what our customers are looking for. Also a considerable service brings us good credit reputation.
Model No | RDW5-1600 | RDW5-2500 | RDWH-3200 | RDW5-4000 | RDW5-6300 | |||||
Rated current (A) | 200,400,630,800 1000,1250,1600 |
1000,1250,1600, 2000,2500 | 2000,2500,2900 3200,3600,4000 |
3200,3600,4000 | 400,050,006,300 | |||||
Neutral rated current In (A) | 100%In | 100%ln | 100%In | 100%In | 50%ln | |||||
Rated operating voltage (V) | AC400/690 | |||||||||
Frequency (Hz) | 50/60Hz | |||||||||
Number of poles | 3P/4P | |||||||||
Rated impulse withstand voltage Uimp(Kv) | Ad12 | |||||||||
Rated isolation voltage Ui(V) | AC 1000 | |||||||||
Power frequency withstand voltage (V) 1min | 3500 (Main circuit) | |||||||||
Rated ultimate short circuit breaking capacity (lcu) kA |
AC400V | 42 | 80 | 100 | 80 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated operating short circuit breaking capacity (lcs) kA |
AC400V | 32 | 65 | 80 | 65 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated withstand current for short- time (Icw) 1s(kA) |
AC400V | 20/30(0.5s) | 65 | 80 | 65 | |||||
AC690V | - | 40 | 50 | - | ||||||
Rated short circuit connection ability (Icm) kA | Electrical life | 7000 | 6500 | 3000 | 3000 | |||||
Mechanical life | 15000 | 15000 | 10000 | 10000 | ||||||
Using type | B type | |||||||||
Breaking time (without any auxiliary delay) | 25-30ms | |||||||||
Closing time | ≤70ms | |||||||||
Operation life (times) 2500A below | 400V electrical life |
8000 | 8000 | 5000 | 1500 | |||||
690V electrical life |
3000 | 2500 | 2000 | 1000 | ||||||
1time/3min; Above 2500A 1time/6min |
Mechanical life (maintenance-free) |
15000 | 12500 | 10000 | 6500 | |||||
Mechanical life (maintenance) |
30000 | 25000 | 20000 | 13000 | ||||||
Wire incoming pattern | Wire to enter from the upper or lower port | |||||||||
Arc distance (mm) | 0 | |||||||||
Installation method | Fixed type or draw-out type |
Draw-out type | Fixed type | ||||||||
Model | Poles | Width (mm) |
Height (mm) |
Depth mm) |
Weight (kg) |
Width (mm) |
Height (mm) |
Depth (mm) |
Weight (kg) |
RDW5-1600 | 3P | 282 | 351 | 345 | 43 | 254 | 320 | 254 | 22 |
4P | 352 | 351 | 345 | 55 | 324 | 320 | 254 | 26.5 | |
RDW5-2500 | 3P | 375 | 435 | 485 | 84 | 368 | 400 | 360 | 47 |
4P | 470 | 435 | 485 | 96 | 463 | 400 | 360 | 56 | |
RDW5-4000 | 3P | 435 | 435 | 515 | 100 | 428 | 400 | 392 | 53 |
4P | 550 | 435 | 515 | 130 | 543 | 400 | 392 | 67 | |
RDW5-6300 | 3P | 780 | 435 | 515 | 195 | 773 | 400 | 441 | 106 |
4P | 895 | 435 | 515 | 225 | 888 | 400 | 441 | 120 |
Overall dimension | Horizontal connection and overall dimension |
![]() |
RDW5-6300/3P Fixed type horizontal connection | Horizontal connection and phase spacing |
![]() |
Installation dimension | The relationship with busbar thickness and current | |
![]() |
Rated current A | Busbar thickness mm |
4000 | 20 | |
50006300 | 30 |
Overall dimension | Horizontal connection and overall dimension |
![]() |
RDW5-6300/4P Fixed type horizontal connection | Horizontal connection and phase spacing |
![]() |
Doorframe installation dimension of RDW5-4000-6300 fixed type | Installation dimension |
![]() |
Overall dimension | Horizontal connection and phase spacing | Installation dimension |
![]() |
RDW5-6300/3P The vertical connection of fixed type | Vertical connection and phase spacing |
![]() |
Overall dimension | Horizontal connection and overall dimension | Installation dimension |
![]() |
RDW5-6300/4P The horizontal connection of fixed type | Horizontal connection and phase spacing |
![]() |
RDW5-6300/4P The vertical connection of fixed type | Vertical connection and phase spacing |
![]() |
Model No | RDW5-1600 | RDW5-2500 | RDWH-3200 | RDW5-4000 | RDW5-6300 | |||||
Rated current (A) | 200,400,630,800 1000,1250,1600 |
1000,1250,1600, 2000,2500 | 2000,2500,2900 3200,3600,4000 |
3200,3600,4000 | 400,050,006,300 | |||||
Neutral rated current In (A) | 100%In | 100%ln | 100%In | 100%In | 50%ln | |||||
Rated operating voltage (V) | AC400/690 | |||||||||
Frequency (Hz) | 50/60Hz | |||||||||
Number of poles | 3P/4P | |||||||||
Rated impulse withstand voltage Uimp(Kv) | Ad12 | |||||||||
Rated isolation voltage Ui(V) | AC 1000 | |||||||||
Power frequency withstand voltage (V) 1min | 3500 (Main circuit) | |||||||||
Rated ultimate short circuit breaking capacity (lcu) kA |
AC400V | 42 | 80 | 100 | 80 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated operating short circuit breaking capacity (lcs) kA |
AC400V | 32 | 65 | 80 | 65 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated withstand current for short- time (Icw) 1s(kA) |
AC400V | 20/30(0.5s) | 65 | 80 | 65 | |||||
AC690V | - | 40 | 50 | - | ||||||
Rated short circuit connection ability (Icm) kA | Electrical life | 7000 | 6500 | 3000 | 3000 | |||||
Mechanical life | 15000 | 15000 | 10000 | 10000 | ||||||
Using type | B type | |||||||||
Breaking time (without any auxiliary delay) | 25-30ms | |||||||||
Closing time | ≤70ms | |||||||||
Operation life (times) 2500A below | 400V electrical life |
8000 | 8000 | 5000 | 1500 | |||||
690V electrical life |
3000 | 2500 | 2000 | 1000 | ||||||
1time/3min; Above 2500A 1time/6min |
Mechanical life (maintenance-free) |
15000 | 12500 | 10000 | 6500 | |||||
Mechanical life (maintenance) |
30000 | 25000 | 20000 | 13000 | ||||||
Wire incoming pattern | Wire to enter from the upper or lower port | |||||||||
Arc distance (mm) | 0 | |||||||||
Installation method | Fixed type or draw-out type |
Draw-out type | Fixed type | ||||||||
Model | Poles | Width (mm) |
Height (mm) |
Depth mm) |
Weight (kg) |
Width (mm) |
Height (mm) |
Depth (mm) |
Weight (kg) |
RDW5-1600 | 3P | 282 | 351 | 345 | 43 | 254 | 320 | 254 | 22 |
4P | 352 | 351 | 345 | 55 | 324 | 320 | 254 | 26.5 | |
RDW5-2500 | 3P | 375 | 435 | 485 | 84 | 368 | 400 | 360 | 47 |
4P | 470 | 435 | 485 | 96 | 463 | 400 | 360 | 56 | |
RDW5-4000 | 3P | 435 | 435 | 515 | 100 | 428 | 400 | 392 | 53 |
4P | 550 | 435 | 515 | 130 | 543 | 400 | 392 | 67 | |
RDW5-6300 | 3P | 780 | 435 | 515 | 195 | 773 | 400 | 441 | 106 |
4P | 895 | 435 | 515 | 225 | 888 | 400 | 441 | 120 |
Overall dimension | Horizontal connection and overall dimension |
![]() |
RDW5-6300/3P Fixed type horizontal connection | Horizontal connection and phase spacing |
![]() |
Installation dimension | The relationship with busbar thickness and current | |
![]() |
Rated current A | Busbar thickness mm |
4000 | 20 | |
50006300 | 30 |
Overall dimension | Horizontal connection and overall dimension |
![]() |
RDW5-6300/4P Fixed type horizontal connection | Horizontal connection and phase spacing |
![]() |
Doorframe installation dimension of RDW5-4000-6300 fixed type | Installation dimension |
![]() |
Overall dimension | Horizontal connection and phase spacing | Installation dimension |
![]() |
RDW5-6300/3P The vertical connection of fixed type | Vertical connection and phase spacing |
![]() |
Overall dimension | Horizontal connection and overall dimension | Installation dimension |
![]() |
RDW5-6300/4P The horizontal connection of fixed type | Horizontal connection and phase spacing |
![]() |
RDW5-6300/4P The vertical connection of fixed type | Vertical connection and phase spacing |
![]() |