Attaining consumer satisfaction is our company’s purpose without end. We will make wonderful endeavours to produce new and top-quality merchandise, satisfy your exclusive requirements and supply you with pre-sale, on-sale and after-sale services for Factory Promotional Aisikai 5000A Hight Quality Draw-out /Fixed Type Acb 3p 4p Air Circuit Breaker Acb, We wholeheartedly welcome buyers all over the globe arrive to visit our manufacturing facility and have a win-win cooperation with us!
Attaining consumer satisfaction is our company’s purpose without end. We will make wonderful endeavours to produce new and top-quality merchandise, satisfy your exclusive requirements and supply you with pre-sale, on-sale and after-sale services for Universal Circuit Breaker and Acb, They are sturdy modeling and promoting effectively all over the world. Never ever disappearing major functions within a quick time, it’s a have to for you personally of fantastic good quality. Guided by the principle of “Prudence, Efficiency, Union and Innovation. the corporation. ake an excellent efforts to expand its international trade, raise its organization. rofit and raise its export scale. We are confident that we’ve been likely to have a bright prospect and to be distributed all over the world in the years to come.
RDW5 series intelligent type Air circuit breaker is applied to power distribution network of AC 50/60Hz, rated operating voltage up to 400V/690V, rated current up to 6300A. It’s mainly used to distribute power and protect circuit and power-supply equipment against damage of faults, such as overload, under-voltage, short-circuit, single-phase grounding, and it has insulation function. Besides, the circuit breaker has various intelligent protect function, can realize bidirectional communication between several breaker and central control computer by its network system, realize remote control function to satisfied the requirements of automatic system control. The circuit breaker conforms the standard of IEC60947-2.
1.ECONOMICAL & FLEXIBLE
2.Quality Parts, Durability, Modular Design, Safe & Reliable
3.HIGHER electrical lifespan
4.More durable & Better performance
5.reduced maintenance cost
6.Innovaive ARC Extinguishing Design
7.Creating“CORE”design “WISDOM”for future
8.Compact in Size
9.Unique Secondary Terminal
10.Flexible Connection
11.Stringent environment capabilitiesAttaining consumer satisfaction is our company’s purpose without end. We will make wonderful endeavours to produce new and top-quality merchandise, satisfy your exclusive requirements and supply you with pre-sale, on-sale and after-sale services for Factory Promotional Aisikai 5000A Hight Quality Draw-out /Fixed Type Acb 3p 4p Air Circuit Breaker Acb, We wholeheartedly welcome buyers all over the globe arrive to visit our manufacturing facility and have a win-win cooperation with us!
Factory Promotional Universal Circuit Breaker and Acb, They are sturdy modeling and promoting effectively all over the world. Never ever disappearing major functions within a quick time, it’s a have to for you personally of fantastic good quality. Guided by the principle of “Prudence, Efficiency, Union and Innovation. the corporation. ake an excellent efforts to expand its international trade, raise its organization. rofit and raise its export scale. We are confident that we’ve been likely to have a bright prospect and to be distributed all over the world in the years to come.
Model No | RDW5-1600 | RDW5-2500 | RDWH-3200 | RDW5-4000 | RDW5-6300 | |||||
Rated current (A) | 200,400,630,800 1000,1250,1600 |
1000,1250,1600, 2000,2500 | 2000,2500,2900 3200,3600,4000 |
3200,3600,4000 | 400,050,006,300 | |||||
Neutral rated current In (A) | 100%In | 100%ln | 100%In | 100%In | 50%ln | |||||
Rated operating voltage (V) | AC400/690 | |||||||||
Frequency (Hz) | 50/60Hz | |||||||||
Number of poles | 3P/4P | |||||||||
Rated impulse withstand voltage Uimp(Kv) | Ad12 | |||||||||
Rated isolation voltage Ui(V) | AC 1000 | |||||||||
Power frequency withstand voltage (V) 1min | 3500 (Main circuit) | |||||||||
Rated ultimate short circuit breaking capacity (lcu) kA |
AC400V | 42 | 80 | 100 | 80 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated operating short circuit breaking capacity (lcs) kA |
AC400V | 32 | 65 | 80 | 65 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated withstand current for short- time (Icw) 1s(kA) |
AC400V | 20/30(0.5s) | 65 | 80 | 65 | |||||
AC690V | - | 40 | 50 | - | ||||||
Rated short circuit connection ability (Icm) kA | Electrical life | 7000 | 6500 | 3000 | 3000 | |||||
Mechanical life | 15000 | 15000 | 10000 | 10000 | ||||||
Using type | B type | |||||||||
Breaking time (without any auxiliary delay) | 25-30ms | |||||||||
Closing time | ≤70ms | |||||||||
Operation life (times) 2500A below | 400V electrical life |
8000 | 8000 | 5000 | 1500 | |||||
690V electrical life |
3000 | 2500 | 2000 | 1000 | ||||||
1time/3min; Above 2500A 1time/6min |
Mechanical life (maintenance-free) |
15000 | 12500 | 10000 | 6500 | |||||
Mechanical life (maintenance) |
30000 | 25000 | 20000 | 13000 | ||||||
Wire incoming pattern | Wire to enter from the upper or lower port | |||||||||
Arc distance (mm) | 0 | |||||||||
Installation method | Fixed type or draw-out type |
Draw-out type | Fixed type | ||||||||
Model | Poles | Width (mm) |
Height (mm) |
Depth mm) |
Weight (kg) |
Width (mm) |
Height (mm) |
Depth (mm) |
Weight (kg) |
RDW5-1600 | 3P | 282 | 351 | 345 | 43 | 254 | 320 | 254 | 22 |
4P | 352 | 351 | 345 | 55 | 324 | 320 | 254 | 26.5 | |
RDW5-2500 | 3P | 375 | 435 | 485 | 84 | 368 | 400 | 360 | 47 |
4P | 470 | 435 | 485 | 96 | 463 | 400 | 360 | 56 | |
RDW5-4000 | 3P | 435 | 435 | 515 | 100 | 428 | 400 | 392 | 53 |
4P | 550 | 435 | 515 | 130 | 543 | 400 | 392 | 67 | |
RDW5-6300 | 3P | 780 | 435 | 515 | 195 | 773 | 400 | 441 | 106 |
4P | 895 | 435 | 515 | 225 | 888 | 400 | 441 | 120 |
Overall dimension | Horizontal connection and overall dimension |
![]() |
RDW5-6300/3P Fixed type horizontal connection | Horizontal connection and phase spacing |
![]() |
Installation dimension | The relationship with busbar thickness and current | |
![]() |
Rated current A | Busbar thickness mm |
4000 | 20 | |
50006300 | 30 |
Overall dimension | Horizontal connection and overall dimension |
![]() |
RDW5-6300/4P Fixed type horizontal connection | Horizontal connection and phase spacing |
![]() |
Doorframe installation dimension of RDW5-4000-6300 fixed type | Installation dimension |
![]() |
Overall dimension | Horizontal connection and phase spacing | Installation dimension |
![]() |
RDW5-6300/3P The vertical connection of fixed type | Vertical connection and phase spacing |
![]() |
Overall dimension | Horizontal connection and overall dimension | Installation dimension |
![]() |
RDW5-6300/4P The horizontal connection of fixed type | Horizontal connection and phase spacing |
![]() |
RDW5-6300/4P The vertical connection of fixed type | Vertical connection and phase spacing |
![]() |
Model No | RDW5-1600 | RDW5-2500 | RDWH-3200 | RDW5-4000 | RDW5-6300 | |||||
Rated current (A) | 200,400,630,800 1000,1250,1600 |
1000,1250,1600, 2000,2500 | 2000,2500,2900 3200,3600,4000 |
3200,3600,4000 | 400,050,006,300 | |||||
Neutral rated current In (A) | 100%In | 100%ln | 100%In | 100%In | 50%ln | |||||
Rated operating voltage (V) | AC400/690 | |||||||||
Frequency (Hz) | 50/60Hz | |||||||||
Number of poles | 3P/4P | |||||||||
Rated impulse withstand voltage Uimp(Kv) | Ad12 | |||||||||
Rated isolation voltage Ui(V) | AC 1000 | |||||||||
Power frequency withstand voltage (V) 1min | 3500 (Main circuit) | |||||||||
Rated ultimate short circuit breaking capacity (lcu) kA |
AC400V | 42 | 80 | 100 | 80 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated operating short circuit breaking capacity (lcs) kA |
AC400V | 32 | 65 | 80 | 65 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated withstand current for short- time (Icw) 1s(kA) |
AC400V | 20/30(0.5s) | 65 | 80 | 65 | |||||
AC690V | - | 40 | 50 | - | ||||||
Rated short circuit connection ability (Icm) kA | Electrical life | 7000 | 6500 | 3000 | 3000 | |||||
Mechanical life | 15000 | 15000 | 10000 | 10000 | ||||||
Using type | B type | |||||||||
Breaking time (without any auxiliary delay) | 25-30ms | |||||||||
Closing time | ≤70ms | |||||||||
Operation life (times) 2500A below | 400V electrical life |
8000 | 8000 | 5000 | 1500 | |||||
690V electrical life |
3000 | 2500 | 2000 | 1000 | ||||||
1time/3min; Above 2500A 1time/6min |
Mechanical life (maintenance-free) |
15000 | 12500 | 10000 | 6500 | |||||
Mechanical life (maintenance) |
30000 | 25000 | 20000 | 13000 | ||||||
Wire incoming pattern | Wire to enter from the upper or lower port | |||||||||
Arc distance (mm) | 0 | |||||||||
Installation method | Fixed type or draw-out type |
Draw-out type | Fixed type | ||||||||
Model | Poles | Width (mm) |
Height (mm) |
Depth mm) |
Weight (kg) |
Width (mm) |
Height (mm) |
Depth (mm) |
Weight (kg) |
RDW5-1600 | 3P | 282 | 351 | 345 | 43 | 254 | 320 | 254 | 22 |
4P | 352 | 351 | 345 | 55 | 324 | 320 | 254 | 26.5 | |
RDW5-2500 | 3P | 375 | 435 | 485 | 84 | 368 | 400 | 360 | 47 |
4P | 470 | 435 | 485 | 96 | 463 | 400 | 360 | 56 | |
RDW5-4000 | 3P | 435 | 435 | 515 | 100 | 428 | 400 | 392 | 53 |
4P | 550 | 435 | 515 | 130 | 543 | 400 | 392 | 67 | |
RDW5-6300 | 3P | 780 | 435 | 515 | 195 | 773 | 400 | 441 | 106 |
4P | 895 | 435 | 515 | 225 | 888 | 400 | 441 | 120 |
Overall dimension | Horizontal connection and overall dimension |
![]() |
RDW5-6300/3P Fixed type horizontal connection | Horizontal connection and phase spacing |
![]() |
Installation dimension | The relationship with busbar thickness and current | |
![]() |
Rated current A | Busbar thickness mm |
4000 | 20 | |
50006300 | 30 |
Overall dimension | Horizontal connection and overall dimension |
![]() |
RDW5-6300/4P Fixed type horizontal connection | Horizontal connection and phase spacing |
![]() |
Doorframe installation dimension of RDW5-4000-6300 fixed type | Installation dimension |
![]() |
Overall dimension | Horizontal connection and phase spacing | Installation dimension |
![]() |
RDW5-6300/3P The vertical connection of fixed type | Vertical connection and phase spacing |
![]() |
Overall dimension | Horizontal connection and overall dimension | Installation dimension |
![]() |
RDW5-6300/4P The horizontal connection of fixed type | Horizontal connection and phase spacing |
![]() |
RDW5-6300/4P The vertical connection of fixed type | Vertical connection and phase spacing |
![]() |