China Wholesale CE Certified Hgc 09/25/50/85/115 DIN Rail Magnetic AC Contactor for Home Use

RDCH8 series AC contactors are mainly suitable for circuits with 50Hz or 60Hz, rated working voltage up to 400V, and rated working current up to 63A. They are used to control household appliances and low inductive loads, and can also control household motor loads. The control power should be reduced accordingly. small. This product can be used in family hotels, apartments and other places to realize automation. Can also be used for other appliances.
This product complies with IEC61095 standard


  • China Wholesale CE Certified Hgc 09/25/50/85/115 DIN Rail Magnetic AC Contactor for Home Use
  • China Wholesale CE Certified Hgc 09/25/50/85/115 DIN Rail Magnetic AC Contactor for Home Use
  • China Wholesale CE Certified Hgc 09/25/50/85/115 DIN Rail Magnetic AC Contactor for Home Use
  • China Wholesale CE Certified Hgc 09/25/50/85/115 DIN Rail Magnetic AC Contactor for Home Use

Product Detail

Application

Parameters

Samples & Structures

Dimensions

We now have a highly efficient workforce to deal with inquiries from consumers. Our goal is “100% consumer fulfillment by our product or service excellent, selling price & our crew service” and get pleasure from a great popularity among clientele. With lots of factories, we can offer a wide vary of China Wholesale CE Certified Hgc 09/25/50/85/115 DIN Rail Magnetic AC Contactor for Home Use, We welcome new and outdated clients to get in touch with us by cell phone or send us inquiries by mail for long term business relationships and accomplishing mutual results.
We now have a highly efficient workforce to deal with inquiries from consumers. Our goal is “100% consumer fulfillment by our product or service excellent, selling price & our crew service” and get pleasure from a great popularity among clientele. With lots of factories, we can offer a wide vary of AC Magnetic Contactor and AC Contactor, The development of our company not only needs the guarantee of quality, reasonable price and perfect service, but also relies on our customer’s trust and support! In the future, we are going to continue with the most qualified and high quality service to offer the most competitive price, Together with our customers and achieve win-win! Welcome to inquiry and consult!

Product Introduction

RDCH8 series AC contactors are mainly suitable for circuits with 50Hz or 60Hz, rated working voltage up to 400V, and rated working current up to 63A. They are used to control household appliances and low inductive loads, and can also control household motor loads. The control power should be reduced accordingly. small. This product can be used in family hotels, apartments and other places to realize automation. Can also be used for other appliances.
This product complies with IEC61095 standard

Features

1.Process guaranteed performance

2.Small volume, large capacity

3.Super-strong wiring capacity

4.Good insulation between phases

5.Super-strong conductivity

6.Low temperature rise and power consumptionWe now have a highly efficient workforce to deal with inquiries from consumers. Our goal is “100% consumer fulfillment by our product or service excellent, selling price & our crew service” and get pleasure from a great popularity among clientele. With lots of factories, we can offer a wide vary of China Wholesale CE Certified Hgc 09/25/50/85/115 DIN Rail Magnetic AC Contactor for Home Use, We welcome new and outdated clients to get in touch with us by cell phone or send us inquiries by mail for long term business relationships and accomplishing mutual results.
China Wholesale AC Magnetic Contactor and AC Contactor, The development of our company not only needs the guarantee of quality, reasonable price and perfect service, but also relies on our customer’s trust and support! In the future, we are going to continue with the most qualified and high quality service to offer the most competitive price, Together with our customers and achieve win-win! Welcome to inquiry and consult!

7

Normal working condition and Installation environment

1.Temperature: -5° +40°, the average temperature of 24 hours should not exceed 35℃

2.Altitude : should not exceed 2000m.

3. The relative humidity: no more than 50%, when Temperature is +40℃. The product can withstand the higher humidityunder lower temperature, for instance, when temperature at +20℃, the product can withstand 90% relative humidity.

4. Pollution class: 2 class

5. Installation type: ll class

6. Installation codition: the angle between the prodouct and vertical plane should not exceed 59.

7. Installation methods: adopt 35mm DIN-Rail

8. Protection class: lP20

Main Technical parameter

4.1 Poles: 1P,2P,3P,4P

4.2 The specification see Table 1, Table 2

Model No. Rated current
(pole)
Using type Rated operational
current(A)
Rated insulation
voltage (V)
Control power
(kw)
Connection
type
RDCH8-25 16(1P/2P) AC-7a 16 500 3.5 With soft-cable:2×2.5mm2
With hard-cable:6mm2
AC-7b 7 500 1
20(1P/2P) AC-7a 20 500 4
AC-7b 8.5 500 1.2
25(1P/2P) AC-7a 25 500 5.4
AC-7b 9 500 1.4
25(3P/4P) AC-7a 40 500 16
RDCH8-63 32(2P) AC-7a 32 500 7.2 With soft-cable:2x10mm2
With hard-cable:25mm2
32(3P/4P) AC-7a 32 500 21
40 (2P) AC-7a 40 500 8.6
40(3P/4P) AC-7a 40 500 26
63(2P) AC-7a 63 500 14
63(3P/4P) AC-7a 63 500 40
Pole Rated current (A) Rated voltage (V) NO NC
1P 16-25 220/230 10
2P 16-25 220/230 20
40-63 02
3P 25 380/400 30
40-63  
4P 25 380/400 40
40-63 04

4.3 Operation performance: Under the condition of the ambient temperature is in the range of -5°C-+40°C, charce theontactor attract coil with rated control power voltage Us and warm it to the stable state, the contactor should attracstably in any value between the 85% and 100% of rated control power voltage Us;t should release and break between 75% and 20%(2P) or 10%(1P) of the rated control power voltage Us.

4.4 Mechanical life: no less than 1 million times.

4.5 Electrical life: no less than 100 thousands times.

4.6 Wiring diagram: see Flg1 to Fig5

20

8

Model No.

6

10:32A and below,3 poles+1NO auxiliary contact
01:32Aand below,3 poles+1NC auxiliary contact
11:40A and above,3 poles+1NO+1NC auxiliary contacts
004:25A and below,4NO main contacts
008:25A and below,2NO+2NC main contacts

 Rated operating current

 AC Contactol

Overall and Installation Dimensions:

9

7

Normal working condition and Installation environment

1.Temperature: -5° +40°, the average temperature of 24 hours should not exceed 35℃

2.Altitude : should not exceed 2000m.

3. The relative humidity: no more than 50%, when Temperature is +40℃. The product can withstand the higher humidityunder lower temperature, for instance, when temperature at +20℃, the product can withstand 90% relative humidity.

4. Pollution class: 2 class

5. Installation type: ll class

6. Installation codition: the angle between the prodouct and vertical plane should not exceed 59.

7. Installation methods: adopt 35mm DIN-Rail

8. Protection class: lP20

Main Technical parameter

4.1 Poles: 1P,2P,3P,4P

4.2 The specification see Table 1, Table 2

Model No. Rated current
(pole)
Using type Rated operational
current(A)
Rated insulation
voltage (V)
Control power
(kw)
Connection
type
RDCH8-25 16(1P/2P) AC-7a 16 500 3.5 With soft-cable:2×2.5mm2
With hard-cable:6mm2
AC-7b 7 500 1
20(1P/2P) AC-7a 20 500 4
AC-7b 8.5 500 1.2
25(1P/2P) AC-7a 25 500 5.4
AC-7b 9 500 1.4
25(3P/4P) AC-7a 40 500 16
RDCH8-63 32(2P) AC-7a 32 500 7.2 With soft-cable:2x10mm2
With hard-cable:25mm2
32(3P/4P) AC-7a 32 500 21
40 (2P) AC-7a 40 500 8.6
40(3P/4P) AC-7a 40 500 26
63(2P) AC-7a 63 500 14
63(3P/4P) AC-7a 63 500 40
Pole Rated current (A) Rated voltage (V) NO NC
1P 16-25 220/230 10
2P 16-25 220/230 20
40-63 02
3P 25 380/400 30
40-63  
4P 25 380/400 40
40-63 04

4.3 Operation performance: Under the condition of the ambient temperature is in the range of -5°C-+40°C, charce theontactor attract coil with rated control power voltage Us and warm it to the stable state, the contactor should attracstably in any value between the 85% and 100% of rated control power voltage Us;t should release and break between 75% and 20%(2P) or 10%(1P) of the rated control power voltage Us.

4.4 Mechanical life: no less than 1 million times.

4.5 Electrical life: no less than 100 thousands times.

4.6 Wiring diagram: see Flg1 to Fig5

20

8

Model No.

6

10:32A and below,3 poles+1NO auxiliary contact
01:32Aand below,3 poles+1NC auxiliary contact
11:40A and above,3 poles+1NO+1NC auxiliary contacts
004:25A and below,4NO main contacts
008:25A and below,2NO+2NC main contacts

 Rated operating current

 AC Contactol

Overall and Installation Dimensions:

9

  • Write your message here and send it to us